Skip to main content
ZJA Series

ZJA6 Force-Guided Relay

Model ZJA6

6-pole (5NO+1NC / 4NO+2NC / 3NO+3NC), 6A, IEC 61810-3 guided contacts, AgSnO2, 10kV isolation

  • Configuration4-Pole
  • ModelZJA4
  • Contact arrangement2NO + 2NC (2H2D)3NO + 1NC (3H1D)
  • Contact load (resistive)6 A 250 V AC / 30 V DC
  • Minimum load5 V DC 10 mA
ZJA6 Force-Guided Relay

Product Information

The ZJA6 is a 6-pole force-guided (mechanically linked) safety relay from the ZJA series. Its forcibly guided contact structure to IEC 61810-3 (Type A) guarantees that NO and NC contacts can never be closed at the same time, providing a reliable, fault-detecting feedback (mirror) contact for machine-safety circuits.

ZJA6 force-guided safety relay

Key features

  • 6-pole contact arrangements — 5NO + 1NC (5H1D), 4NO + 2NC (4H2D) or 3NO + 3NC (3H3D)
  • Forcibly guided (mechanically linked) contacts per IEC 61810-3, Type A structure
  • 6 A switching capability — 6 A 250 V AC / 30 V DC (resistive)
  • Low input power — 500 mW coil
  • High insulation — 10 kV surge (input–output), 4000 V AC dielectric (coil–contacts)
  • AgSnO₂ contacts — gold-plated version available (suffix R)
  • Wide DC coil range — 5 / 6 / 9 / 12 / 18 / 24 / 36 / 48 / 110 V DC
  • PCB terminals; flux-proofed; body approx. 40 × 13 × 24 mm, ~23 g
  • UL Class F insulation system; CE, TÜV Rheinland, cULus; RoHS

Typical applications:
Safety relay modules, emergency-stop and guard/door-monitoring circuits, light-curtain and two-hand control, and machine-safety controllers — wherever forcibly guided (mirror) feedback contacts are required.

Ordering (select code): ZJA6 / {coil V DC} — {5H1D | 4H2D | 3H3D} T {R} — T = AgSnO₂ contact material, R = gold-plated contacts; e.g. ZJA6/24—4H2DT (24 V DC coil).

Manufactured by Wenzhou Jinhong (WZJH), a China relay manufacturer — OEM / ODM welcome.

Characteristics

Configuration4-Pole
ModelZJA4
Contact arrangement2NO + 2NC (2H2D)3NO + 1NC (3H1D)
Structural classificationType A force-guided (mechanically linked) contacts — IEC 61810-3
Contact materialAgSnO₂ (gold-plated version available, suffix “R”)
Contact load (resistive)6 A 250 V AC / 30 V DC
Minimum load5 V DC 10 mA
Contact resistance≤100 mΩ (1 A 6 V DC)
Max. switching voltage400 V AC / 30 V DC
Max. switching current6 A
Max. switching power1500 VA / 180 W
Electrical endurance1×10⁵ operations (1NO, 6 A 30 V DC resistive) · 1×10⁵ operations (1NO, 6 A 250 V AC resistive) — room temp., 1 s on / 9 s off
Mechanical endurance1×10⁷ operations
Coil power360 mW
Coil voltage5 / 6 / 9 / 12 / 18 / 24 / 36 / 48 / 110 V DC
Operate / release time≤20 ms / ≤20 ms
Insulation resistance1000 MΩ (500 V DC)
Dielectric strength4000 V AC 1 min (coil–contacts) · 1500 V AC 1 min (open contacts) · 2500 V AC 1 min (contact groups 7-8 / 9-10), 4000 V AC 1 min (other groups)
Surge voltage10 kV (1.2/50 µs, coil–contacts) · 5 kV (1.2/50 µs, between contact groups)
Vibration resistanceNO/NC: 10–55 Hz 1.5 mm double amplitude · NO: 55–200 Hz, 98 m/s² · NC: 55–200 Hz, 49 m/s²
Shock resistance100 m/s² (stability) / 980 m/s² (strength)
Humidity5–85% RH
TerminationPCB terminals
EncapsulationFlux-proofed
Body size (L × W × H)approx. 40 × 13 × 24 mm
Weight~20 g
ApprovalsCE · TÜV Rheinland · cULus; UL Class F insulation system; RoHS

Specifications

Wiring diagrams (bottom view) — 6-pole contact arrangements 5NO + 1NC (5H1D), 4NO + 2NC (4H2D) or 3NO + 3NC (3H3D); DC coil on terminals 1–0. Performance curves: maximum switching capacity (AC / DC resistive), electrical endurance (1NO, 250 V AC resistive, room temp., 1 s on / 9 s off — typical values) and coil temperature rise (0 A / 6 A load, at 85 °C and room temperature).

ZJA6 force-guided relay 5no + 1nc wiring (bottom view)ZJA6 — 5H1D5NO + 1NC wiring (bottom view)🔍 Click to enlargeZJA6 force-guided relay 4no + 2nc wiring (bottom view)ZJA6 — 4H2D4NO + 2NC wiring (bottom view)🔍 Click to enlargeZJA6 force-guided relay 3no + 3nc wiring (bottom view)ZJA6 — 3H3D3NO + 3NC wiring (bottom view)🔍 Click to enlargeZJA6 maximum switching capacity curveMaximum switching capacityAC / DC resistive load🔍 Click to enlargeZJA6 electrical endurance curveElectrical endurance1NO · 250 V AC resistive · typical🔍 Click to enlargeZJA6 coil temperature rise curveCoil temperature risevs. % of rated coil voltage🔍 Click to enlarge

Dimensions

Dimensions (mm) — PCB-terminal safety relay, body approx. 40 × 13 × 24 mm (L × W × H), terminal grid 5.08 / 10.16 mm pitch; PCB layout (bottom view) with 14 × Φ1.4 holes. Unless noted, tolerances: ±0.2 mm (≤1 mm), ±0.3 mm (1–5 mm), ±0.4 mm (>5 mm); PCB layout ±0.1 mm.

ZJA6 force-guided safety relay dimension drawingZJA6outline — front, side & bottom views🔍 Click to enlargeZJA6 PCB layout drawing (bottom view)PCB layoutbottom view, 14 × Φ1.4🔍 Click to enlarge