Product guide
Compact K16/22K16 Emergency Stops: Panel Integration
Plan rear clearance, actuator access and servicing for compact K16/22K16 emergency-stop assemblies in a machine control panel.
In this article
A compact emergency-stop assembly can be useful where a control enclosure has limited depth. Its integration must still allow the actuator, contacts and wiring to function as specified throughout installation and maintenance.
Measure more than body depth.
Allow space for connected conductors, their bend radius and access to the contact components. Check the mounting drawing and panel thickness limits. The assembly should not be forced against the enclosure wall or a neighbouring component.
Keep the operating point accessible.
Check the installed position from the operator’s working location. Surrounding controls or guards must not prevent intended operation. Verify the specified release method and use the device markings and documentation to identify its function.
Commission the complete function.
Mechanical installation is only part of the work. The machine’s safety design determines monitoring, stopping behaviour and reset arrangements. The validation should address the complete function, including the requirement that releasing an emergency-stop actuator does not by itself restart the equipment.
For family selection, compare K16 and 22K16. This article focuses on enclosure integration; the K16/22K16 selection checklist covers the information to specify before ordering.
Original product video
Watch the original video on Tencent Video if the embedded player is unavailable.
Emergency-stop integration review
This article focuses on integration and service access. Use the companion selection guide when comparing the physical device families.
| Check | Information to record |
|---|---|
| Operator access | Confirm the intended location and identification in the panel layout. |
| Reset behaviour | Document the required reset and separate restart arrangement. |
| Service and validation | Retain device instructions and the complete safety-function validation record. |
Can releasing an emergency-stop button serve as the restart command?
Release must not itself initiate restart. The machine's control design needs the appropriate reset and restart arrangements specified for the complete safety function.
Explore the products
Catalogue examples from the ranges discussed. Open a model to check its configuration and technical details.
K16 Small Head Emergency Stop Switch (Short Contact)
View model