Product Information
The ZJ41S is an ultra-thin (5 mm wide) solid-state relay (SSR) — 28 × 5 × 15 mm, single-row in-line PCB mounting. Fully electronic and maintenance-free: no mechanical action, no noise, no contact wear, with a built-in RC snubber and high EMC for harsh environments. AC-output types use a TRIAC; DC-output types use a power transistor (low-RDS 6 A option). Zero-crossing switching (random type optional).
Key features
- Solid-state (SSR) — maintenance-free, long life; no mechanical action, noise, arcing or contact wear
- Ultra-thin 5 mm — 28 × 5 × 15 mm; single-row in-line PCB mount, space-saving
- Three output families — 2A (AC, TRIAC, 2 A) · 2D (DC, transistor, 2 A) · 6D (low-RDS DC, 6 A)
- Zero-crossing turn-on / current-zero turn-off (random type optional)
- Built-in RC surge-absorption snubber; high EMC for harsh environments
- Wide DC input 5–60 V (05 / 12 / 24 / 32 / 60); input impedance 0.5–2.2 kΩ
- 2500 V AC input-to-output isolation; ≥1000 MΩ; −30…+80 °C; ~20 g
Characteristics
| Output family | 2A — AC output |
| Output device | TRIAC |
| Max. load current | 2 A |
| Load voltage | 75–264 V AC (45–65 Hz) |
| Surge current (non-repeating) | 30 A |
| Peak withstand voltage | 600 V |
| ON-state voltage drop | ≤1.2 V @ 2 A |
| Turn-off leakage | ≤3 mA @ 240 VAC |
| Min. load current | 20 mA |
| Reset time | ½ cycle + ≤1 ms |
| Switching | Zero-cross (random opt.) |
| Input voltage | 5 V DC (05) · 12 V DC (12) · 12–24 V DC (24) · 3–32 V DC (32) · 60 V DC (60) |
| Input impedance | 0.5 kΩ (5 V) · 1.5 kΩ (12 V) · 2.2 kΩ (24 V) |
| Dielectric (input ↔ output) | 2500 V AC, 50/60 Hz, 1 min |
| Insulation resistance | ≥1000 MΩ |
| Use ambient temperature | −30 … +80 °C (−30 … +100 °C with derating; no condensation / icing) |
| Humidity | 45% … 85% RH |
| Vibration | 10–55 Hz, double amplitude 0.75 mm |
| Shock | 1000 m/s² |
| Unit weight | approx. 20 g |
| Dimensions | 28 × 5 × 15 mm |
| Mounting | Single-row in-line PCB |
| Ordering code | ZJ41S-{2A | 2D | 6D}{output A}{load: 2 = 24–240 VAC, 6 = 5–60 VDC}{input: 05/12/24/32/60}{trigger: 0 = zero-cross, 1 = random} (e.g. ZJ41S-2A2024-0) |
| Example models | AC: ZJ41S-2A20{05/12/24/32/60} · DC: ZJ41S-2D61{05/12/24/60} · low-RDS: ZJ41S-6D61{05/12/24/60} |
| Load · Resistive | 2A 24~240VAC |
| Load · Motor | 1/8HP,240VAC |
| Rated voltage | 2A:24~240VAC / 2D:5~60VDC / 6D:5~60VDC |
| Pick-up voltage | 5VDC (4-6VDC), 12VDC (9.2-14.4VDC), 24VDC (9.2-28.8VDC), 60VDC (60VDC) |
| Maximum voltage | 2A: 600Vpeak / 2D/6D: 60Vpeak |
| Maximum continuous current | 2A: 2A / 2D: 2A / 6D: 6A |
| Maximum inrush current | 2A: 30A / 2D: 16A / 6D: 80A |
| Minimum inrush current | 2A: 20mA / 2D:0.02mA / 6D: 0.02mA |
| Max. rated power | 360W(60VDC) |
| Electrical endurance | ≥3 x 10⁷ operations |
| Mechanical endurance | N/A |
| Protection class | RT II / IP20 |
| Storage & transport | -40℃~+85℃ |
| Altitude | ≤ 2000 m |
| Operating time | ≤1ms |
| Release time | ≤1ms |
| Atmospheric pressure | 86~106KPa |
Specifications
Wiring diagram (bottom view) and PCB layout — single-row in-line terminals; input on one side, switched output on the other. For AC output, zero-crossing turn-on minimises switching noise; observe input polarity for DC input.
ZJ41S
Dimensions
Dimensions (mm) — ultra-thin body 28 × 5 × 15 mm; single-row in-line PCB mounting. Outline and bottom-view PCB layout:
Contact us on WhatsApp
Choose how to continue. If WhatsApp Web is unavailable, open the app or copy our number.