Skip to main content
ZJ41F Series

ZJ41S Interface Relay

Model ZJ41S

5mm SSR, TRIAC/transistor output, zero-cross, RC snubber, high EMC

  • Output family2A — AC output
  • Output deviceTRIAC
  • Max. load current2 A
  • Load voltage75–264 V AC (45–65 Hz)
  • Peak withstand voltage600 V
ZJ41S Interface Relay

Product Information

The ZJ41S is an ultra-thin (5 mm wide) solid-state relay (SSR) — 28 × 5 × 15 mm, single-row in-line PCB mounting. Fully electronic and maintenance-free: no mechanical action, no noise, no contact wear, with a built-in RC snubber and high EMC for harsh environments. AC-output types use a TRIAC; DC-output types use a power transistor (low-RDS 6 A option). Zero-crossing switching (random type optional).

Key features

  • Solid-state (SSR) — maintenance-free, long life; no mechanical action, noise, arcing or contact wear
  • Ultra-thin 5 mm — 28 × 5 × 15 mm; single-row in-line PCB mount, space-saving
  • Three output families — 2A (AC, TRIAC, 2 A) · 2D (DC, transistor, 2 A) · 6D (low-RDS DC, 6 A)
  • Zero-crossing turn-on / current-zero turn-off (random type optional)
  • Built-in RC surge-absorption snubber; high EMC for harsh environments
  • Wide DC input 5–60 V (05 / 12 / 24 / 32 / 60); input impedance 0.5–2.2 kΩ
  • 2500 V AC input-to-output isolation; ≥1000 MΩ; −30…+80 °C; ~20 g

Characteristics

Output family2A — AC output
Output deviceTRIAC
Max. load current2 A
Load voltage75–264 V AC (45–65 Hz)
Surge current (non-repeating)30 A
Peak withstand voltage600 V
ON-state voltage drop≤1.2 V @ 2 A
Turn-off leakage≤3 mA @ 240 VAC
Min. load current20 mA
Reset time½ cycle + ≤1 ms
SwitchingZero-cross (random opt.)
Input voltage5 V DC (05) · 12 V DC (12) · 12–24 V DC (24) · 3–32 V DC (32) · 60 V DC (60)
Input impedance0.5 kΩ (5 V) · 1.5 kΩ (12 V) · 2.2 kΩ (24 V)
Dielectric (input ↔ output)2500 V AC, 50/60 Hz, 1 min
Insulation resistance≥1000 MΩ
Use ambient temperature−30 … +80 °C (−30 … +100 °C with derating; no condensation / icing)
Humidity45% … 85% RH
Vibration10–55 Hz, double amplitude 0.75 mm
Shock1000 m/s²
Unit weightapprox. 20 g
Dimensions28 × 5 × 15 mm
MountingSingle-row in-line PCB
Ordering codeZJ41S-{2A | 2D | 6D}{output A}{load: 2 = 24–240 VAC, 6 = 5–60 VDC}{input: 05/12/24/32/60}{trigger: 0 = zero-cross, 1 = random} (e.g. ZJ41S-2A2024-0)
Example modelsAC: ZJ41S-2A20{05/12/24/32/60} · DC: ZJ41S-2D61{05/12/24/60} · low-RDS: ZJ41S-6D61{05/12/24/60}
Load · Resistive2A 24~240VAC
Load · Motor1/8HP,240VAC
Rated voltage2A:24~240VAC / 2D:5~60VDC / 6D:5~60VDC
Pick-up voltage5VDC (4-6VDC), 12VDC (9.2-14.4VDC), 24VDC (9.2-28.8VDC), 60VDC (60VDC)
Maximum voltage2A: 600Vpeak / 2D/6D: 60Vpeak
Maximum continuous current2A: 2A / 2D: 2A / 6D: 6A
Maximum inrush current2A: 30A / 2D: 16A / 6D: 80A
Minimum inrush current2A: 20mA / 2D:0.02mA / 6D: 0.02mA
Max. rated power360W(60VDC)
Electrical endurance≥3 x 10⁷ operations
Mechanical enduranceN/A
Protection classRT II / IP20
Storage & transport-40℃~+85℃
Altitude≤ 2000 m
Operating time≤1ms
Release time≤1ms
Atmospheric pressure86~106KPa

Specifications

Wiring diagram (bottom view) and PCB layout — single-row in-line terminals; input on one side, switched output on the other. For AC output, zero-crossing turn-on minimises switching noise; observe input polarity for DC input.

ZJ41SZJ41S

Dimensions

Dimensions (mm) — ultra-thin body 28 × 5 × 15 mm; single-row in-line PCB mounting. Outline and bottom-view PCB layout:

ZJ41S dimension drawingZJ41S🔍 Click to enlarge